|Regulators
-
-
The responsiveness of ITV1000 to 3000 series regulators depends on the volume on the OUT side.
As a guideline, when there is no volume, it is about 0.4 seconds.
For the ITV1000 and ITV2000, there is a high-speed response time type available using the special order part number suffix “-X88.”
For this product, as a guideline, when there is no volume (no load), it is about 0.1 second.
For more information, refer to the special order options in the ITV series catalog, which can be found here.
For ITV1000 to 3000 series regulators, although the responsiveness tends to be faster with gain adjustment, stability may be lost and hunting may occur.
For details, refer to the ITV series operation manual, which can be found here.
Note) The high-speed response time type (special order part number suffix “-X88”) does not have a gain/sensitivity adjustment function.