If the IN side pressure is not 0.7 MPa, correct the flow rate with the absolute pressure ratio before use using the following formula.
absolute pressure ratio = (actual IN side pressure) / (IN side pressure in the characteristics graph)
If the IN side pressure is 0.5 MPa, it can be corrected as follows. (0.5 + 0.1) / (0.7 + 0.1) = 0.75 (the flow rate in the graph x 0.75)