Support / Contact Us » FAQ

|Chemical Liquid Valves (Fluoropolymer Equipment)
-
What is the max. operating temperature of TL, TLM, TH, and TD series fluoropolymer tubing?
-
The max. operating temperature of each fluoropolymer tubing series is as follows.
Note that the max. operating pressure will drop depending on the operating temperature. Refer to the catalog, which can be found here.
Max. operating temperature of the TL/TIL, TLM/TILM, and TD/TID series (fixed use)
Air/inert gases: 260°C
Water: 100°C
Max. operating temperature of the TH/TIH series (fixed use)
Air/inert gases: 200°C
Water: 100°C