|Air Cylinders
-
-
Lock release side: Turn the lock release bolt clockwise with a hexagonal wrench until it stops. (It is the lock side which is designed to prevent the product from falling out.)
Lock side: Turn the lock release bolt counterclockwise with a hexagonal wrench until it stops, and then tighten it an additional 1/6 rotation counterclockwise from the point where it stops to lock it.
If the lock release bolt is not completely in the locked position, the lock may not operate properly or air may leak from the lock release bolt, preventing the lock from being released.
The tightening torque is not specified as the lock release bolt is not a part that secures the product.
Do not tighten or loosen the release bolts excessively. Also, do not tighten them with a pneumatic or electric screwdriver because it may damage internal parts of the product.
For further details, refer to the excerpts from the MWB series “Specific Product Precautions” below.