|Air Cylinders
-
Can any of the 3 piping ports of an MXH-Z series compact slide table be used?
-
MXH-Z series slide tables can be piped from 3 directions. Refer to the following information for the pressure port and operating direction. Operate the product after changing the position of the plug according to the operating conditions. Be sure to check that there is no air leakage from the plug. If there is a small amount of leakage, remove the plug once, and check the seat surface before reinserting it. When changing the port position, be sure to order a plug using the replacement plug part number “MXH-P” (2 pcs./set). To change the piping direction when ordering, use the special order part number suffix “-XC3□.”
Note) When plugging the MXH6 axial piping port, be careful not to tighten it excessively as the plug will come into contact with the steel ball inside and cause air leakage. As a guide, the plug should not be recessed more than 0 to 1 mm below the cylinder surface after tightening.
Plugging the MXH6 axial piping port